Left ventricular pressure-volume loop measurements for wild-type and SR-BIΔCT mice

Maximum Left Ventricular Volume, μl Minimum Left Ventricular Volume, μl Cardiac Output, μl/min Ejection Fraction, % Stroke Work, mmHg·μl dP/dtmax, mmHg/s dP/dtmin, mmHg/s
WT (n = 7) 45.9 ± 2.4 27.2 ± 1.5 5.9 ± 0.3 31.7 ± 1.3 1,703 ± 96 8,438 ± 653 −7,661 ± 630
SR-BIΔCT (n = 6) 45.3 ± 1.4 27.3 ± 0.8 5.4 ± 0.3 28.8 ± 1.5 1,718 ± 116 8,638 ± 645 −8,199 ± 593
P value >0.05 >0.05 >0.05 >0.05 >0.05 >0.05 >0.05

dP/dtmax and dP/dtmin indicate maximal and minimal rate of changes in pressure over time and measure systolic contractility and diastolic relaxation, respectively.