Skip to main content
. 2016 Sep 30;311(6):H1392–H1408. doi: 10.1152/ajpheart.00463.2016

Table 3.

Left ventricular pressure-volume loop measurements for apoE KO and SR-BIΔCT/apoE KO mice

Maximum Left Ventricular Volume, μl Minimum Left Ventricular Volume, μl Cardiac Output, μl/min Ejection Fraction, % Stroke Work, mmHg·μl +dP/dt, mmHg/s −dP/dt, mmHg/s
apoE KO (n = 6) 41.5 ± 1.9 22.3 ± 1.1 6.6 ± 0.5 36.5 ± 1.5 1,947 ± 137 10,737 ± 454 −8,084 ± 400
SR-BIΔCT/apoE KO (n = 8) 59.5 ± 6.8 40.9 ± 4.6 4.7 ± 0.3 21.0 ± 1.6 1,331 ± 120 6,404 ± 654 −5,318 ± 574
P value 0.04 0.005 0.005 <0.0001 0.006 0.0003 0.0032