Skip to main content
. Author manuscript; available in PMC: 2017 Dec 1.
Published in final edited form as: IEEE Trans Med Imaging. 2016 Jun 9;35(12):2513–2523. doi: 10.1109/TMI.2016.2578939

TABLE I.

Hypothesis Testing To Compare CIM1524 Data For Apex, Base, And Lateral Surface Measurements

CIM Property Frequency range (kHz) with p-value < 0.05
Lateral-Apex Apex-Base Lateral-Base
With OR R 20–100 1–100 - {50} 1–100
X 9–400 1–400 1–600
|Z| 20–400 1–200 - {50} 1–300
Φ 20–500 1–500 2–500

Without OR R 2–90 - {3,6} 1–90 2–500
X 7–400 - {20} 1–400 1–400 - {20,40, 50}
|Z| 20–400 1–90 1–200
Φ 2–400 -{3,6,300} 1–900 - {600} 2–500

OR: Outlier Removal (data beyond 5th and 95th percentile was removed)

The numbers represent range of signal frequencies for which the null hypothesis that the two datasets had same population mean can be rejected at a significance level of 0.05 (p-value<0.05). A t-test was performed. The numbers in the brackets list the frequencies that are exception within the given range of signal frequencies.