Skip to main content
. Author manuscript; available in PMC: 2018 Jan 1.
Published in final edited form as: Clin Transplant. 2016 Nov 24;31(1):10.1111/ctr.12864. doi: 10.1111/ctr.12864

Table 3.

Unadjusted and adjusted change in echocardiogram morphology and function at 12 and 24 months compared to the baseline evaluation at 1 month following kidney transplant

Unadjusted Outcome 12 month effect 95% CI P Value 24 month effect 95% CI P Value Overall P
LV mass index −10.21 −15.52, −4.90 <0.001 −16.21 −23.37, −9.04 <0.001 <0.001
LV mass −12.61 −22.71, −2.51 0.016 −22.64 −36.30, −8.98 0.001 0.002
Ejection fraction 1.57 0.18, 2.97 0.029 2.23 0.39, 4.07 0.019 0.021
LA volume index −2.95 −4.80, −1.09 0.002 −4.87 −7.34, −2.40 <0.001 <0.001

Adjusteda
Outcome
12 month effect 95% CI P Value 24 month effect 95% CI P Value Overall P

LV mass index −10.82 −16.28, −5.36 <0.001 −15.59 −22.90, −8.27 <0.001 <0.001
LV mass −13.96 −24.48, −3.43 0.010 −21.47 −35.59, −7.35 0.003 0.003
Ejection fraction 1.54 0.09, 2.98 0.039 2.62 0.72, 4.52 0.008 0.013
LA volume index −3.31 −5.19, −1.44 <0.001 −5.12 −7.60, −2.64 <0.001 <0.001

95% Confidence Interval: Lower bound, Upper bound

a

Each outcome was adjusted for age at transplant, race, gender, time on dialysis, cardiovascular disease, Mean arterial pressure, estimated glomerular filtration rate, diabetes, and body mass index