Table 4.
Application | Delivery device | Frequency | Acoustic energy/power | Delivery protocol |
---|---|---|---|---|
ECWT for ischemic heart disease [27] | Extracorporeal shock wave generator mounted in-line with trans-thoracic echocardiogram | N/A (individual shock waves) | 0.9 mJ/mm2 | 200 shock waves per spot, 40–60 spots per session, three sessions per week for three months |
HIFU epicardial pulmonary vein isolation for AF [35–37] | UltraCinch and UltraWand devices secured epicardially around pulmonary veins | 3.8–6.4 MHz | 15–130 W | Three sequential stages of ablation corresponding to different depths: endocardial to epicardial. Ten minutes total for UltraCinch, one minute for UltraWand |
HIFU endocardial pulmonary vein isolation for AF [41] | 12 French balloon-tipped endocardial catheter | 9 MHz | 45 W | Circumferential ablations, 40–90 s per vein, multiple ablations may be required |
HIFU epicardial VT ablation [46]a | 14 French epicardial catheter | 6.4 MHz | 6 W | 60 s per ablation point, multiple points per animal |
Animal studies only