Table 5.
Compound | Conc (nM) |
Extraction recovery Average ± SD (%) |
Intra-day | Inter-day | Matrix effect Average ± SD (%) |
||
---|---|---|---|---|---|---|---|
Accuracy (bias, %) |
Precision (CV, %) |
Accuracy (bias, %) |
Precision (CV, %) |
||||
40 | 107.40 ± 8.95 | 90.84 | 2.9 | 81.60 | 1.13 | 94.75 ± 5.05 | |
CPT-11 | 200 | 109.14 ± 8.45 | 97.22 | 2.33 | 95.86 | 3.53 | 91.86 ± 4.07 |
1000 | 107.07 ± 1.77 | 97.63 | 0.15 | 81.70 | 2.95 | 85.8 ± 6.39 | |
40 | 107.02 ± 2.68 | 96.66 | 1.69 | 80.29 | 3.61 | 88.26 ± 2.79 | |
SN-38 | 200 | 106.9 ± 4.51 | 98.97 | 0.94 | 99.43 | 8.88 | 92.31 ± 2.84 |
1000 | 102.49 ± 2.64 | 93.65 | 2.98 | 89.46 | 4.78 | 115.4 ± 8.43 | |
8 | 83.8 ± 13.56 | 103.78 | 12.25 | 84.09 | 7.17 | 81.17 ± 4.31 | |
SN-38G | 40 | 93.87 ± 16.84 | 105.9 | 3.11 | 100.45 | 0.39 | 81.92 ± 6.08 |
200 | 86.63 ± 16.83 | 94.36 | 2.48 | 106.97 | 9.10 | 97.84 ± 1.4 |