Table 2. p-values and classification performances (accuracy) of individual QUS parameters for differentiating responders from non-responders at weeks 1, 4 and 8.

Week 1 Week 4 Week 8
ΔMBF Accuracy 61 ± 8 65 ± 5 85 ± 5
p-value 0.042 <0.005 <0.005
ΔSI Accuracy 55 ± 8 65 ± 11 74 ± 6
p-value 0.034 0.010 <0.005
ΔACE Accuracy 54 ± 8 64 ± 4 60 ± 10
p-value <0.005 0.042 0.259
ΔAAC Accuracy 58 ± 8 64 ± 9 69 ± 8
p-value 0.404 0.069 0.135
ΔSS Accuracy 53 ± 8 62 ± 7 63 ± 15
p-value 0.424 0.368 0.727
ΔASD Accuracy 54 ± 9 61 ± 9 60 ± 13
p-value 0.382 0.377 0.570
ΔSAS Accuracy 62 ± 7 58 ± 8 69 ± 7
p-value 0.606 0.678 0.590

Parameters are sorted from highest to lowest accuracy at week 4. The bold entry indicates the best performance. Reported values are mean and standard deviation of the accuracies in percentages. Results were obtained by running the classification 10 times using 10 random samples from responders group