Guidelines from the American Society of Echocardiography Pediatric and Congenital Heart Disease Council regarding accurate measurement of the aortic root [8].

Guidelines for the Measurement of the Proximal Aorta
  1. Measurements are made in systole, at maximum expansion.

  2. Measurements are the intraluminal dimension (also known as inner-ed).

  3. Vascular measurements are made perpendicular to the long axis of the vessel.