Table 2.

Localized unsigned and signed border positioning error at blood vessel and steep slope locations (Mean ± SD in μm).

Error Blood Vessel Steep Slope


Unsigned Signed Unsigned Signed
Initialization 18.56±13.11 13.23±15.45 24.12±16.86 21.23±19.65
Lee et al. [2] 11.09± 9.68 10.34±12.24 14.35±10.11 13.44±13.11
Proposed method 3.92± 2.01 -1.23± 2.87 4.83± 3.25 3.56± 3.87