Table 1. MRV protocol.
| Sequence | TR | TE | Flip angle | FOV (mm) | Matrix | Slice thickness/interval | Fat saturation |
|---|---|---|---|---|---|---|---|
| TOF axial pelvis | 509 | 7.9 | 60 | 261×380 | 320×132 | 3/3 | Yes |
| Coronal T1W GRE pre contrast & post contrast arterial and venous phases (3 stations1) | Yes | ||||||
| Abdomen | 3.05 | 1.01 | 25 | 375×500 | 384×202 | 1.4/1.4 | |
| Thigh | 3.03 | 0.99 | 22 | 500×500 | 384×269 | 1.6/1.6 | |
| Calf | 3.31 | 1.07 | 25 | 453×500 | 448×244 | 1.6/1.6 | |
1, subtraction images are generated by the post-processing of pre and post contrast arterial phase images and displayed as coronal MIP images.