Skip to main content
. 2016 Dec;6(6):533–543. doi: 10.21037/cdt.2016.11.14

Table 1. MRV protocol.

Sequence TR TE Flip angle FOV (mm) Matrix Slice thickness/interval Fat saturation
TOF axial pelvis 509 7.9 60 261×380 320×132 3/3 Yes
Coronal T1W GRE pre contrast & post contrast arterial and venous phases (3 stations1) Yes
   Abdomen 3.05 1.01 25 375×500 384×202 1.4/1.4
   Thigh 3.03 0.99 22 500×500 384×269 1.6/1.6
   Calf 3.31 1.07 25 453×500 448×244 1.6/1.6

1, subtraction images are generated by the post-processing of pre and post contrast arterial phase images and displayed as coronal MIP images.