Skip to main content
. 2004 Oct;70(10):6299–6301. doi: 10.1128/AEM.70.10.6299-6301.2004

TABLE 4.

Accuracy of the quantification of L. monocytogenes organisms by RTi-PCR in three different food matricesa

Approx no. of CFU/g Relative accuracy
Raw pork Frankfurter sausages Fermented sausages
106 101.12 ± 0.30 99.77 ± 0.52 98.62 ± 1.30
105 97.99 ± 1.37 100.60 ± 0.41 101.77 ± 3.85
104 100.16 ± 4.11 99.48 ± 2.56 103.80 ± 1.45
103 100.88 ± 2.89 100.12 ± 2.15 94.98 ± 2.53
102 BQ BQ BQ
a

Samples were filtered through nylon membranes with 11-μm pores. Approximate numbers of CFU per gram are initial sizes of the inocula. Relative accuracy was calculated as a percentage of log numbers of CFU per gram obtained by the RTi-PCR-based method and the L. monocytogenes standard method of enumeration (5). Values are expressed as means ± standard deviations of the results obtained in three independent experiments. All samples tested positive (n = 9). BQ, below the range of quantification.