Table 2.

Method validation data of the detected ginsenosides

Compounds Calibration curve R2 Linear range (μg/mL) Repeatability
(n = 3, RSD, %)
Stability
(24 h, RSD, %)
Recovery (n = 6, %)
LOD
(ng/mL)
LOQ
(ng/mL)
Mean RSD
G-Rg1 y = 392.004654x – 2454.104831 0.9984 0.0098–7.84 0.36 6.99 90.47 4.40 16.17 24.46
G-Re y = 299.734277x – 1791.661821 0.9985 0.0098–7.84 0.94 7.08 90.20 4.54 18.30 42.63
20(S)-G-Rh1 y = 620.207468x – 3461.353416 0.9971 0.0096–7.68 0.44 8.80 94.55 7.03 6.08 16.48
20(S)-G-Rg2 y = 446.870617x – 3996.127372 0.9971 0.0121–9.68 2.76 8.41 93.24 3.58 21.22 28.12
G-Rb1 y = 38.734528x + 276.504261 0.9967 0.0206–16.48 1.45 8.23 85.29 6.83 38.66 178.59
G-Rb2 y = 110.324768x – 940.621364 0.9972 0.0212–16.96 1.83 7.26 92.71 3.75 35.46 156.12
G-Rd y = 330.118348x – 1789.047109 0.9983 0.0126–10.08 3.29 7.78 90.54 4.26 19.19 41.97

LOD = limit of detection; LOQ = limit of quantitation; RSD = relative standard deviation.