Left ventricle volumes at diastole (EDV) and systole (ESV) and ejection fraction (EF) measured by cardiac CT or echocardiography and either Simpson’s, or Cylinder-hemiellipsoid methods in pigs with chronic myocardial infarction (MI) and controls

Control (n = 5) MI (n = 9) All (n = 14) p
EDV (mL)
 Cardiac CT 140 ± 19 227 ± 96 196 ± 88 0.07
 Modified Simpson’s 124 ± 18 225 ± 126 a 189 ± 111 0.1
 Cylinder hemiellipsoid 112 ± 22 230 ± 140 b 188 ± 125 0.09
ESV (mL)
 Cardiac CT 49 ± 2 137 ± 79 106 ± 76 0.03
 Modified Simpson’s 59 ± 14 149 ± 98 c 117 ± 89 0.07
 Cylinder hemiellipsoid 47 ± 14 150 ± 94 d 113 ± 90 0.03
EF (%)
 Cardiac CT 64 ± 4 42 ± 10 50 ± 14 <0.001
 Modified Simpson’s 53 ± 5 37 ± 8 e 42 ± 11 0.0015
 Cylinder hemiellipsoid 59 ± 7 38 ± 6 f 46 ± 12 <0.001

a P = 0.86 vs. Cardiac CT, b P = 0.85 vs. Cardiac CT, c P = 0.72 vs. Cardiac CT, d P = 0.82 vs. Cardiac CT, e P = 0.1 vs. Cardiac CT, f P = 0.3 vs. Cardiac CT