Table V.

Performance comparison among 2DUS, SWE, CEUS and their combined use in the diagnosis of benign and malignant thyroid nodules (%).

Pathological result

Method Type Benign Malignant Sensitivity Specificity PPV NPV Accuracy
2DUS Benign 141 39 71.32 77.04 69.78 78.33 74.60
Malignant 42 97
SWE Benign 154 21 84.55a 84.15a 79.86a 88.00a 84.32a
Malignant 29 115
CEUS Benign 158 17 87.5a 86.33a 82.63a 90.28a 86.83a
Malignant 25 119
SWE+CEUS Benign 170 9 93.38a,b 92.89a,b 90.71a,b 94.97a,b 93.10a,b
Malignant● 13 127
a

Compared with conventional 2DUS, P<0.05.

b

Compared with SWE and CEUS, P<0.05. ▼, positive results for one or both methods; ●, negative results for both methods; SWE, shear wave elastography; CEUS, contrast-enhanced ultrasound; 2DUS, two-dimensional ultrasound; PPV, positive predictive value; NPV, negative predictive value.