Skip to main content
. 2016 Oct 18;12(6):3675–3679. doi: 10.3892/etm.2016.3813

Table III.

Comparison of the incidence of stent restenosis.

Group No. of cases Restenosis rate 1 month after operation, cases (%) Target lesion diameter loss ratio, % Restenosis rate 1 year after operation, cases (%) Target lesion diameter loss rate, %
Control 91 18 (19.78) 35.4±10.2 23 (25.27) 42.3±15.4
Observation 55 20 (36.36) 76.8±15.6 28 (50.91) 86.5±18.2
t/χ2 4.897 9.632 9.911 13.232
P-value 0.027 0.000 0.002   0.000