Published in final edited form as: Ann Thorac Surg. 2012 Oct 25;95(1):105–110. doi: 10.1016/j.athoracsur.2012.08.078

TABLE 2.

Differences in mitral annular geometric parameters between controls and patients with FMR (cases).

Annular Dimensions Controls
(n=15)
Cases
(n=34)
P value
Anteroposterior diameter 3.0 cm ± 0.1 4.0 cm ± 0.14 <0.01
Anterolateral–Posteromedial
diameter
3.6 cm ± 0.1 4.3 cm ± 0.1 <0.01
Commissural diameter 3.5 cm ± 0.5 4.4 cm ± 0.7 <0.01
Annular Circumference 11.4 cm ± 0.5 14.1cm ±0.4 <0.01
2D Annular Area 8.7 cm2 ± 0.79 14.2 cm2± 0.8 <0.01
3D Annular Area 9.6 cm2± 3 14.6 cm2± 5 <0.01
Anterior Leaflet Area 6.4 cm2± 2 10.0 cm2± 3 <0.01
Posterior Leaflet Area 6.1 cm2± 2 9.0 cm2± 3 <0.01
Annular Shape
Nonplanarity Angle 136° ± 11 155° ± 15 <0.01
Max Nonplanarity Angle 140° ± 10 158° ± 15 <0.01
Circularity Index 0.85 ± 0.02 0.93 ± 0.01 <0.01
Tenting Height 10.0 mm ± 0.85 11.7mm ± 0.77 0.13
Tenting Volume 3.5mm3± 2.0 6.2mm3± 3.5 0.01
Tenting Volume Fraction 24% ± 11 30% ± 21 0.36
Aorto-Mitral Angle 112° ±14 119° ± 15 0.12
Annular Excursion
Maximum Vertical Annular
Displacement
8.3 mm ± 3 5.8 mm ± 2 <0.01
Maximum Vertical Annular
Displacement Velocity
32 mm/s ± 13 26 mm/s ± 8 0.05
Maximum Vertical Annular
Acceleration
26 mm/s2± 15 18 mm/s2± 12 0.04

Values are described as mean ± standard deviation.

FMR: functional mitral regurgitation