Skip to main content
. 2016 Dec 19;8(1):349–366. doi: 10.1364/BOE.8.000349

Table 1. Summary of data from the pair of fellow porcine corneas. The CCT and Young’s moduli are represented as the 95% confidence interval of the respective data from all OCE-measured meridional angles for a given IOP and IOP change direction. The standard deviation of rθ is the standard deviation of rθ from all OCE-measured meridional angles for a given IOP.

Cornea 1 (Untreated)
Cornea 2 (CXL-treated)
IOP Direction IOP
(mmHg)
CCT (µm) Young’s modulus (kPa) Standard Deviation of rθ (kPa) CCT (µm) Young’s modulus (kPa) Standard Deviation of rθ (kPa)
+ 15 956;971 14.7;22.2 9.8 677;682 33.5;51.9 22.7
20 880;889 23.8;43.9 25.1 638;646 87.7;156.2 95.3
25 837;846 42.0;74.4 38.7 621;629 127.8;213.5 119.3

  30 810;818 72.6;117.4 56.4 594;605 228.1;417.9 244.5

- 25 829;838 59.8;95.7 43.1 619;628 149.4;244.7 121.9
20 867;877 29.6;55.3 30.6 628;638 109.9;191.2 103.2
15 940;953 22.2;32.9 14.2 678;688 51.2;91.7 49.5