(A) The image shows the tip of the needle within the ethiodized oil contrast blush; (B) a post-processing reconstruction obtained after the fusion of the pre-procedural CBCT (showing contrast blush) and post-insertion of the needle acquisition: the image confirms the correct position of the needle; (C) fluoroscopic image shows the correct position of the needle within the contrast blush; (D) fluoroscopic image obtained at the end of the procedure shows ethiodized oil that derives from the lymphography and in part from the embolization.