Comparative Dose-volume characteristics between sequential boost and integrated boost plans

Base of Tongue Sequential boost SIB p value
 Volume 13.2 cc 12.5 cc p = 0.13
 Mean 60.2 Gy 65.2 Gy p = 0.63
 Max 72.8 Gy 71.8 Gy P = 0.85
 V30 92.2% 97.5% p = 0.58
 V70 41.3% 47% p = 0.09
Larynx
 Volume 25.79 cc 26.8 cc p = 0.08
 Mean 49.4 Gy 43.8 Gy p = 0.06
 Max 74.3 Gy 73.6 Gy p = 0.31
 V30 72% 60% p = 0.06
 V70 10.7% 19.5% p = 0.06
Esophagus
 Volume 7.8 cc 6.9 cc p = 0.09
 Mean 25.6 Gy 27.2 Gy p = 0.19
 Max 54.0 Gy 49.2 Gy p = 0.08
 V30 34.6% 37.5% p = 0.31
 V70 0.3% 0% p = 0.08