Table III.

Reconstruction results using classical interpolation method and the proposed method over non-noisy MR images

2mm 3mm 4mm 5mm 6mm 7mm

Slice
Thickness
PSNR
(dB)
SSIM PSNR
(dB)
SSIM PSNR
(dB)
SSIM PSNR
(dB)
SSIM PSNR
(dB)
SSIM PSNR
(dB)
SSIM
Nearest Neighbor 27.105 0.9634 23.886 0.9178 22.098 0.8719 20.939 0.8305 20.142 0.7963 19.373 0.7576
Bilinear 28.254 0.9673 25.004 0.9287 22.859 0.8794 21.600 0.8385 20.639 0.7981 19.793 0.7575
Bicubic 29.613 0.9767 25.619 0.9388 23.418 0.8944 22.050 0.8527 21.033 0.8114 20.133 0.7700
B-Spline 30.008 0.9780 25.713 0.9389 23.460 0.8933 22.089 0.8509 21.027 0.8064 20.129 0.7638
Proposed Method 31.555 0.9849 26.791 0.9544 24.355 0.9174 22.803 0.8793 21.635 0.8382 20.635 0.7950