TABLE 2.
Parameter | Ig (μg/ml)
|
|||
---|---|---|---|---|
G | M | A | Total | |
Experimental anti-PnPs 14 | 25.18 | 1.51 | 1.74 | 34.07 |
Assigned anti-PnPs 14 | 27.77 | 1.20 | 1.95 | 37.06 |
Relative differencea | 9% | 26% | 11% | 8% |
Relative difference = 100 × [(experimental − assigned)/assigned].
The quantity of anti-PnPs serotype 14 antibodies in pneumococcal standard reference serum lot 89-S was determined from the mean of eight separate EIA, using the anti-PnPs serotype 6B EIA as the reference, run concurrently with anti-PnPs EIA for 12 serotypes. The values obtained by this cross-standardized method were compared to the previously assigned anti-PnPs serotype 14 values (20).