Skip to main content
. 2015 Jan 1;25(1):3–14. doi: 10.1089/thy.2014.0096

Table 2.

Ultrasound Features Predictive of Malignant Lymph Node Involvement

Criterion Sensitivity Specificity
Size >1 cm 68% 75%
Shape (ratio of long axis to short axis <2.0) 46% 64%
Punctate calcifications 46% 100%
Peripheral hypervascularity 86% 82%

Adapted from Leboulleux et al. (10).