Table 3. Influence of coexistent metals on platinum determination in Hep G2 cell samples.

Metals Added concentration (ug/L) Sample Pta concentration (ug/L) Number of the experiment Mean Average recovery (%)
1 (ug/L) 2 (ug/L) 3 (ug/L) 4 (ug/L) 5 (ug/L) 6 (ug/L)
Ca 90.9 95.3 85.5 93.3 94.5 96.9 101.2 99.4 95.1 99.8
Mg 90.9 95.3 104.0 96.5 100.8 94.0 93.5 99.3 98.0 102.9
Fe 1.1 75.0 74.8 74.1 67.1 71.1 73.5 67.2 71.3 95.1
Zn 12.2 102.2 111.5 95.4 92.6 103.2 95.3 98.1 99.4 97.2
Cu 1.2 102.2 102.6 111.1 106.1 106.6 104.2 101.9 105.4 103.1
Mn 1.2 102.2 96.0 95.8 108.9 107.5 107.6 107.6 103.9 101.7
K 12.2 102.2 101.6 103.3 97.0 110.8 101.6 106.3 103.4 101.2
Na 12.2 102.2 107.0 104.9 100.2 101.7 100.4 95.6 101.6 99.4

Notes.

a

Platinum.