. 2016 May 5;89(1063):20160116. doi: 10.1259/bjr.20160116

Table 1.

Results for protons and C ions for variations in parameter x, the relative biological effect (RBE) uncertainty factor (for example, x = 1.2 indicates a 20% RBE increment, x = 1 indicates an RBE of 1 etc.), for intended 2-Gy-equivalent fractional doses

  x = 0.95 x = 1.0 x = 1.05 x = 1.1 x = 1.15 x = 1.20 x = 1.25
Protons
dH (Gy) 1.91 1.82 1.73 1.65 1.58 1.51 1.45
% change (=dH/1.82×100) (105.3) (100) (95.2) (90.9) (87.0) (83.3) (80)
ΔdH (Gy) (=dH −1.82) 0.1 0 −0.09 −0.17 −0.24 −0.30 −0.36
BED Gy3 per fraction 3.20 3.42 3.65 3.88 4.12 4.36 4.61
% BED change (compared with x = 1) 93.7 100 106.8 113.6 120.5 127.6 134.9
Carbon ions
dH (Gy) 0.84 0.8 0.76 0.73 0.70 0.67 0.64
% change (=dH/1.82 × 100) (105.3) (100) (95.2) (90.9) (87.0) (83.3) (80)
ΔdH (Gy) (=dH −1.82) 0.04 0 −0.04 −0.07 −0.10 −0.13 −0.16
BED Gy3 per fraction 3.14 3.32 3.50 3.68 3.86 4.05 4.23
% BED change (compared with x = 1) 94.6 100 105.4 110.9 116.5 122.2 127.6

BED, biological effective dose.

dH is the dose of the particle radiation, which is 1.82 Gy (protons) and 0.8 Gy (C ions).

Δ is the physical change in the dose.

Gy3 is the BED units for the case of α/β=3Gy.