Table 2.

Royal London Hospital MRI protocol for imaging of craniocervical junction and cervical spine for ligamentous and neuroparenchymal traumatic injury evaluation (Siemens Avanto 1.5 Tesla MRI scanner)

Sequence TR (ms) TE (ms) FOV (mm) NEX (averages) Matrix Slice thickness (mm)
Sag T2 3500 83 240 2 269 × 384 3/3.3
Sag T1 TSE 740 11 240 3 269 × 384 3/3.3
Sag STIR 4000 30 240 2 205 × 256 3/3.3
Ax T1 TSE 610 12 200 2 190 × 320 4/4.4
Ax T2 8250 91 220 2 196 × 320 4/4.4
T2 3DSPACE COR 1500 129 160 1.6 261 × 256 0.8

TR time to repetition, TE time to echo, FOV field of view, NEX number of excitations, Sag sagittal, Ax axial, TSE turbo spine echo, SPACE sampling perfection with application-optimised contrasts using different flipangle evolutions, COR coronal