Table 4.

Proficiency parameters for sample pretreatment methods reviewed.

Treatment Conditions Limit of detection Reproducibility (RSD, %) Recovery (%) Detection system Reference
Ultrasound 40°C, pH 7.15 0.03–0.05 μg mL−1 <4.1 81.89–92.42 LC-UV [42]
SPE Britton-Robinson buffer, 0.008 mol L−1, pH 10 4.4–12 μg kg−1 <11.0 76.5–95.5 LC-DAD [43]
Pressure 3 min, 60°C, 65 bars 10.0–15.0 μg kg−1 <8.4 75.6–102.9 LC-UV [44]
MSPE pH 10.0 2–9 μg L−1 <2.7 99.7–101.2 Capillary electrophoresis [45]
SPE CH3CN/CH3CO2H (8 : 2) 0.61–10.34 μg kg−1 <7.3 81.5–101.4 [46]
MSPD C6H14, CH3CN : CH2Cl2 (1 : 1) 7–34 mg kg−1 <6.1 80.6–99.2 LC-DAD [47]
MI-SPE CH3OH, 70°C, 105 bars Not indicated Not indicated Not indicated LC-ITMS [48]
SPE CH3CN : CH3OH (1 : 1), 0.1 mol L−1 phosphoric acid Not indicated Not indicated 96–98 Spectrophotometry [49]
SPE McIlvaine/EDTA buffer 1.5–8.0 μg L−1 <3.6 70.3–107.4 DAD [49]