Table 4.

Column analysis matrix

Material Model Temperature Distribution Analysis Scheme

Group ID Specimen EC 3 NIST Uniform Non-uniform Modified Newton-Raphson Modified Riks PFE (kN)
A 1 W8×35–T300 x x x 1134
2 W8×35–T500 x x x 921
3 W8×35–T600 x x x 639
4 W14×53–T500 x x x 1260
5 W14×53–T600 x x x 865

B 6 W8×35–T300 x x x 1392
7 W8×35–T500 x x x 1141
8 W8×35–T600 x x x 788
9 W14×53–T500 x x x 1442
10 W14×53–T600 x x x 1091

C 11 W8×35–T300 x x x 1171
12 W8×35–T500 x x x 921
13 W8×35–T600 x x x 605
14 W14×53–T500 x x x 1267
15 W14×53–T600 x x x 869

D 16 W8×35–T300 x x x 1417
17 W8×35–T500 x x x 1135
18 W8×35–T600 x x x 827
19 W14×53–T500 x x x 1445
20 W14×53–T600 x x x 1097

E 21 W8×35–T300 x x x 1320
22 W8×35–T500 x x x 903
23 W8×35–T600 x x x 443
24 W14×53–T500 x x x 1217
25 W14×53–T600 x x x 641

F 26 W8×35–T300 x x x 1646
27 W8×35–T500 x x x 1244
28 W8×35–T600 x x x 815
29 W14×53–T500 x x x 1713
30 W14×53–T600 x x x 1189