Table 2. Employed Sampling Instruments in Indoor Air Quality Assessment.
| Parameters | Equipment | Manufacturer |
|---|---|---|
| Temperature & Humidity | Thermo hygrometer; YESAIR Air Quality Monitor |
Oregon Scientific; Critical Environment TechnologiesTM |
| Air Movement | Kestrel 100 weather meter | Nielsen Kellerman |
| Carbon Monoxide (CO) | Aspirating Pump AP20 with Gas Detector Tube System Range: 1–50 ppm; YESAIR Air Quality Monitor |
Kitagawa, Japan Product Code: 106SC; Critical Environment TechnologiesTM |
| Carbon Dioxide (CO2) | Aspirating Pump AP20 with Gas Detector Tube System Range: 100–1,500 ppm; YESAIR Air Quality Monitor |
Kitagawa, Japan Product Code: 126B; Critical Environment TechnologiesTM |
| Formaldehyde (CH2O) | Aspirating Pump AP20 with Gas Detector Tube System Range: 0.05–4 ppm; YESAIR Air Quality Monitor |
Kitagawa, Japan Product Code: 171SC; Critical Environment TechnologiesTM |
| Ozone (O3) | Aspirating Pump AP20 with Gas Detector Tube System Range: 0.05–4 ppm; YESAIR Air Quality Monitor |
Kitagawa, Japan Product Code: 182U; Critical Environment TechnologiesTM |
| Total Volatile Organic Compounds (TVOC) | TVOC detector; YESAIR Air Quality Monitor |
ION Science Ltd. Serial Number: 09-01372; Critical Environment TechnologiesTM |
| Respirable Dust | APEX Sampling Pump with Higgins-Dewell cyclone and 37 mm, 5 μm PVC membrane; YESDUST Particulates Sensor |
Casella UK Serial Number: 0663065; Critical Environment TechnologiesTM |
| Carbon Dioxide (CO2) | Total Resources and Environmental Monitoring System (TREMS) | SRAS Bhd. Telasia Symtonic K3311170VC |