Fig. 1. The DLBCL-on-a-chip microvasculature model is fabricated using common laboratory items.

Fig. 1

A) An overall schematic highlighting the embedded DLBCL hydrogel (Left) within the PDMS macrostructure (Right) B) Schematic of the fabrication process. PDMS was molded around a stainless steel wire, and a hole was punched out. This hole was filled in with the DLBCL hydrogel and allowed to polymerize. The hydrogel was then sealed with a plasma bonded glass coverslip. The stainless steel wire was removed and the resulting microchannel was cultured with endothelial cells.