Two-gene system: comparison of average errors for Euler, expEuler, Heun, and expHeun methods.

Step size Euler expEuler Heun expHeun
1 1.6832 4.4456 × 10−3 2.9451 × 10−1 2.1871 × 10−3
1/2 9.21627 × 10−1 2.4275 × 10−3 4.0230 × 10−2 1.0848 × 10−3
1/4 5.1922 × 10−1 1.4028 × 10−3  1.0096 × 10−2 9.5000 × 10−4
1/8 1.8775 × 10−1 1.0103 × 10−3 2.7588 × 10−3 9.4565 × 10−4
1/16 5.0636 × 10−2 9.0239 × 10−4 1.1937 × 10−3 9.4830 × 10−4
1/32 1.8282 × 10−2 8.9416 × 10−4 9.8137 × 10−4 9.4942 × 10−4