Table 5.
p53-mdm2 system: comparison of average errors for Euler, expEuler, Heun, and expHeun methods.
| Step size | Euler | expEuler | Heun | expHeun |
|---|---|---|---|---|
| 1/16 | 3.5455 | 9.7152 × 10−3 | 3.3784 | 2.47061 × 10−3 |
| 1/32 | 1.3141 × 10−3 | 5.3681 × 10−3 | 1.7446 × 10−4 | 1.2767 × 10−3 |
| 1/64 | 6.5825 × 10−4 | 2.7553 × 10−3 | 5.9564 × 10−5 | 4.383 × 10−4 |
| 1/128 | 3.0970 × 10−4 | 1.3769 × 10−3 | 4.7031 × 10−5 | 1.1482 × 10−4 |