Table 4. Results of the Regression Analysis for the Dose-Response Curve of the FDXR and RAD51 Genes and P Values for Significant Differences Between the 6 and 18 MV Beam Energies (1, 2).

Gene/Energy Equation R2 P Value
0.2 Gy 0.5 Gy 2 Gy 4 Gy
FDXR/6 MV y = -51.198 x2 + 773.2 x + 743.75 0.9987 0.2 70a 0.51 3a 0.001b 0.008b
FDXR/18 MV y = -243.23 x2 + 2003.1 x + 897.15 0.9952
RAD51/6 MV y = -210.47 x2 + 1215.9 x + 529.91 0.9996 827a 0.2 75a 0.04 0b 0.12 7b
RAD51/18 MV y = -307.62 x2 + 1832.4 x + 847.15 0.9706

aNon-significant differences between the copy numbers of genes at the same doses at 6 and 18 MV photon beam energies.