Skip to main content
. 2017 Jan;9(1):117–122. doi: 10.21037/jtd.2017.01.27

Table 2. Comparison of the intraoperative blood gas analysis and perioperative surgical parameters between the two-intubation approaches.

Intra-operative blood gas analysis OLV TLV P value
Pre-PCO2 39.25 (4.6) 37.50 (5.2) 0.371
1 hr PCO2 48.20±7.83 47.44±7.71 0.662
2 hr PCO2 43.99±6.96 43.57±6.60 0.756
Pre-PO2 74.65 (10.5) 75.50 (11.4) 0.209
1 hr PO2 124.45 (106) 207.10 (283.0) 0.002
2 hr PO2 296.90 (290.7) 382.20 (205.7) 0.035
Pre-SO2 96.50 (2.0) 96.30 (2.0) 0.376
1 hr SO2 99.00 (3.0) 100.00 (1.0) 0.001
2 hr SO2 100.00 (0.0) 100.00 (0.0) 0.086

Data shown as mean ± SD or numeric value. OLV, one-lung ventilation; TLV, two-lung ventilation.