Skip to main content
. 2015 Aug 20;5(3):1366–1378. doi: 10.3390/nano5031366

Table 1.

Maximum pore size of alumina/polymer membranes with different CNTs loadings.

Sample Pressure When the First Bubble Appeared (kPa) * Maximum Pore Size (nm)
Pristine 200 178
0.2 wt % CNTs 205 174
0.5 wt % CNTs 240 148
1.0 wt % CNTs 245 145

Notes: * The pressure showing in this table is the average value of two tests and the standard error is within 10 kPa.