Skip to main content
. 2017 Feb 13;5(3):e13124. doi: 10.14814/phy2.13124

Table 9.

Difference in the upper or lower 95% LOA for averaged parameters that are detectable with 80% powera (repeatability cohort)

Tidal breathing parameters REST1 versus REST2 Combined REST versus POST‐CST
RR (brpm) 0.2 0.2
tI (sec) 0.1 0.1
tE (sec) 0.1 0.07
tTot (sec) 0.04 0.03
tI/tE 0.08 0.09
tI/tTot 0.02 0.02
IE50 0.26 0.23

brpm, breaths per minute; IE50, inspiratory to expiratory flow ratio at 50% tidal volume (or SLP equivalent); LOA, limits of agreement; POST‐CST, post exercise measurement session; REST1, resting breathing measurement session 1; REST2, resting breathing measurement session 2; RR, respiratory rate; tE, expiratory time; tI, inspiratory time; tI/tE, inspiratory/expiratory time ratio; tI/tTot, duty cycle; tTot, total breath time.

a

Minimum detectable change using the current sample (80% power) and the averaged parameters.