Skip to main content
. 2017 Feb 15;83(5):e03151-16. doi: 10.1128/AEM.03151-16

TABLE 2.

Effects of pore size of filter bag on the recovered number of Salmonella organisms and the volume obtained after filtration

Pore size of filter bag (μm) Recovery after filtrationa
Salmonella/ml (log CFU/ml) Vol (ml)b Total no. of Salmonella (log CFU)
63 3.0 ± 0.1 35 ± 7 4.6 ± 0.1
<250 3.1 ± 0.1 65 ± 7 4.9 ± 0.1
280 3.0 ± 0.0 80 ± 7 4.9 ± 0.0
500 2.9 ± 0.1 95 ± 7 4.9 ± 0.1
a

Data are shown are the means and 95% confidence intervals.

b

The added volume was 100 ml.