Dataset Location Duration, Year No. Houses Energy Sensors Data Recorded Readings Freq.
Agg.=Aggregate, App.=Appliance, Sub.=Power circuit, e.g., the fuse which all appliances in a single room are connected to.
           
Types is in relation to appliance groups in situations where only appliances were monitored.
           
Active Power (P), Reactive Power (Q), Apparent Power (S), Energy (E), Frequency (f), Power Factor (pf), Phase Angle (Φ), Voltage (V) and Current (I). ACS-F1 and ACS-F2 datasets contain appliance signatures obtained in a laboratory setting instead of real homes.            
ACS-F132 CHE 2*1 h sessions, 2013 N/A 100 App. (10 types) V, I, f, P, Q, Φ 10 secs
ACS-F220 CHE 2*1 h sessions, 2013 N/A 225 App. (15 types) V, I, f, P, Q, Φ 10 secs
AMPds16 CAN 1 year, 2012 1 21 App. V, I, f, pf, P, Q, S, E 1 min
AMPds217 CAN 2 years, 2012 1 21 App. V, I, f, pf, P, Q, S, E 1 min
BLUED14 USA 8 days, 2011 1 Agg. V, I 12 kHz
DRED33 NED 6 months, 2015 1 Agg., 12 App. P 1 Hz
ECO22 CHE 8 months, 2012 6 Agg., 6–10 App. V, I, P, Q, Φ 1 Hz
GREEND34 AUT, ITA 1 year, 2013 9 9 App. P 1 Hz
HES2 GBR 1 month (255 houses), 251 Agg., 1–10 Sub., P 10 min
    1 year (26 houses), 2010   13–51 App.    
iAWE35 IND 73 days, 2013 1 Agg., 10 App. Agg. V, I, f, P, Q, S, E, Φ 1 Hz
          App. V, I, f, P, S, E, Φ  
IHEPCDS18 FRA 4 years, 2006 1 Agg., 3 Sub. Agg. P, Q 1 min
          Sub. E  
REDD13 USA 3–19 days, 2011 6 Agg., 9–24 App. Agg. V, P Agg. 15 kHz
          App. P App. 3 secs
REFIT GBR 2 years, 2013 20 Agg., 9 App. P 8 secs
Smart*23 USA 3 months, 2012 3 House A. Agg., 26 Sub., Agg. V, f, P, S Agg. 1 Hz
        55 App. Sub. V, f, P, S Sub. 1 Hz
        House B, C. Agg., 21 Sub. App. P App. 2.5 secs
Tracebase21 DEU 1,883 days, 2012 onwards 15 158 App. (43 types) P 1 Hz
UK-DALE19 GBR 655 days, 2012 5 Agg., 5–54 App. Agg. V, I Agg. 16 kHz
          App. P App. 6 secs