Skip to main content
. 2017 Feb 21;7:43015. doi: 10.1038/srep43015

Table 4. Univariable and multivariable logistic regression investigating the association between morphological predictors and detection of secondary glaucoma.

Predictors Univariate Analysis
Multivariate Analysis
OR 95% CI P OR 95% CI P
AOD500 (μm) 0.34 0.11–1.85 0.43 0.22 0.09–1.77 0.12
TIA (degrees) 0.97 0.87–1.09 0.62 1.02 0.88–1.17 0.82
ACD (mm) 0.63 0.11–3.60 0.60 0.34 0.28–2.83 0.33
CCT 0.99 0.71–1.05 0.09 0.95 0.69–1.12 0.12
High insertion of iris 3.97 1.31–10.75 0.01 3.40 1.03–11.17 0.03
Peripheral anterior synechiae 1.34 1.03–4.76 0.04 1.26 0.72–3.99 0.10
IOL implantation in sulcus 1.75 1.18–5.26 0.02 1.39 1.07–4.85 0.04

AOD500 = angle-opening distance at 500 μm; TIA = trabecular-iris angle; ACD = Anterior chamber depth; CCT = central corneal thickness; IOL = introcular lens; OR = odds ratio; CI = 95% confidence intervals.