Skip to main content
. 2015;8(Spec Iss 4):150–153.

Table 2.

Causes of unsuccessful laryngoscopy in the two groups

Variable Inappropriate tongue position Blade outside vallecula Laryngoscope loss in the posterior larynx P-value
1st attempt DL 18 (72) 7 (28) - 0.066
VL 23 (92) 2 (8) -
2nd attempt DL 11 (44) 11 (44) 1 (4) 0.08
VL 4 (16) 12 (48) 9 (36)
3rd attempt DL 3 (12) 11 (44) 1 (4) 0.141
VL - 10 (40) 3 (12)
VL: GlideScope video laryngoscopy; DL: direct laryngoscopy