Skip to main content
. Author manuscript; available in PMC: 2017 May 1.
Published in final edited form as: Eur Radiol. 2016 Aug 23;27(5):1787–1794. doi: 10.1007/s00330-016-4559-0

Table 2.

Summary of the inter-modality (a) and inter-observer (b) agreement for AAA diameter measurements

a) Inter-modality agreement
Diameter on MRI (mm) Diameter on CTA (mm) SDa (between methods) CVb Bias LOAc ICCd
 Reader 1 49.8± 12.0 50.7 ± 12.3 1.4 2.8 % −0.8 (−3.6, 1.9) 0.991
 Reader 2 50.3± 12.1 50.3 ± 12.2 1.3 2.6 % −0.04 (−2.6, 2.5) 0.994
b) Inter-observer agreement
Reader 1 (mm) Reader 2 (mm) SDa (between readers) CVb Bias LOAc ICCd
 MRI 49.8± 12.0 50.3 ± 12.1 1.2 2.5 % 0.5 (−2.0, 2.9) 0.994
 CTA 50.7± 12.3 50.3 ± 12.2 1.2 2.3 % −0.3 (−2.6, 1.9) 0.995
a

standard deviation;

b

coefficient of variance;

c

limit of agreement;

d

intra-class coefficient.