Skip to main content
. 2017 Feb 27;18:6. doi: 10.1186/s40510-017-0161-5

Table 3.

Percentage changes in the various models according to the material of each component

Factor Group Absolute crown displacement (mm) Absolute apex displacement (mm) Equivalent elastic strain in PDL Von Mises stress in bracket (MPa)
Adhesive RMGI Ref (100%) Ref (100%) Ref (100%) Ref (100%)
Composite resin +0% +0.2% −0.4% +0%
Bracket Titanium Ref (100%) Ref (100%) Ref (100%) Ref (100%)
Stainless steel +10.8% +2.8% +3.1% +29.4%
Ceramic +18.8% +4.2% +30.3% +59.3%
Ligature Elastomeric Ref (100%) Ref (100%) Ref (100%) Ref (100%)
Stainless steel +3.0% +0.8% −12.9% +3.7%
Wire TMA Ref (100%) Ref (100%) Ref (100%) Ref (100%)
Stainless steel +150.0% +84.2% +126.5% +117.9%

PDL periodontal ligament, TMA titanium molybdenum alloy, RMGI resin-modified glass ionomer cement, Ref reference category consisting of the average across models with this material