Skip to main content
. 2017 Feb 27;18:6. doi: 10.1186/s40510-017-0161-5

Table 4.

Sensitivity analysis by octupling the total number of elements in the model

Original Sensitivity (×8)
Elements Elements
Adhesive 2351 18,808
Bone 6835 54,680
Bracket 28,791 230,328
Left ligature 597 4776
Right ligature 597 4776
PDL 5777 46,216
Tooth 10,518 84,144
Wire 12,557 100,456
Absolute crown displacement (mm) Absolute apex displacement (mm) Equivalent elastic strain in PDL Von Mises stress in bracket (MPa)
Original 0.006 0.036 0.146 237.975
Sensitivity 0.004 0.031 0.156 297.663
Difference −0.002 −0.005 +0.010 +21.756
Difference % −33.3% −13.9% +6.8% +9.1%

PDL periodontal ligament