Table 4.

Examination of systematic error in noise-free simulations.

Vein center position (x,y) Orientation of magnetic field PPC (ϵv) PPC (ppm) MIV (ϵv) MIV (ppm) ICF (ϵv) ICF (ppm) ICF (ϵR) ICF (R^)
(0,0) 1.2% 0.32 1.8% 0.32 1.2% 0.32 0.6% 1.31
(0.25, 0.25) 0.7% 0.31 6.8% 0.39 5.5% 0.37 −10.8% 1.16
(0.5, 0.5) 3.4% 0.35 7.9% 0.41 6.9% 0.39 −12.4% 1.14
(0,0) 90° 0.1% 0.30 0.7% 0.31 −0.1% 0.30 1.4% 1.32
(0.25, 0.25) 90° 1.3% 0.32 7.5% 0.40 5.9% 0.38 −9.4% 1.18
(0.5, 0.5) 90° 4.2% 0.36 8.9% 0.42 6.9% 0.39 −11.5% 1.15

Exact QSM measurements are denoted ppm (ppm = χvein−χbackground). The vein center position is relative to the corner of the voxel [e.g., at (0.5, 0.5) the center of the voxel is aligned with the center of the vein]. All values are reported as signed values, i.e., negative values are under-estimates of the true value. The ground truth OEF was 22%, χvein−χbackground was 0.30 and radius was 1.3 voxels.