Skip to main content
. 2017 Feb 28;17:19. doi: 10.1186/s12880-017-0189-5

Table 3.

Results for automatically calculated peak velocities and atrial contraction. Manual and automatic measurement results of automatically calculated peak emptying velocity, peak filling velocity, and atrial contraction as mean ± SD in the left and right side of the heart. Comparison of automatic tracking vs manual measurements as correlation R value and bias ± SD. The validation was performed on n = 20 subjects. The atrial contraction is given in % of the atrioventricular plane displacement (AVPD) in end systole

Measure Manual Automatic R Bias ± SD
Left peak emptying velocity [cm/s] −57 ± 12 −49 ± 8 0.63 −7.6 ± 9.0
Right peak emptying velocity [cm/s] −77 ± 18 −77 ± 12 0.74 −0.4 ± 12.0
Left peak filling velocity [cm/s] 72 ± 29 49 ± 15 0.74 23.0 ± 20.4
Right peak filling velocity [cm/s] 79 ± 28 68 ± 23 0.85 10.8 ± 14.8
Left atrial contraction [%] 31 ± 11 32 ± 7 0.49 −1.5 ± 9.9
Right atrial contraction [%] 38 ± 9 35 ± 7 0.39 3.3 ± 9.0