Skip to main content
. 2016 Feb 4;16(6):428–433. doi: 10.14744/AnatolJCardiol.2015.6569

Table 2.

Two dimensional echocardiographic and Doppler parameters of the study population

Dippers Non-dippers P
LVEDD, mm 45±3.9 46.3±3.3 0.1
LVESD, mm 31.5±2.8 31.6±3.3 0.68
Ejection fraction, % 64.1±3.5 62.9±4.2 0.92
Left atrial diameter, mm 34.9±3.1 36.8±2.9 0.16
IVST, mm 9.7±1.8 11.1±1.5 0.001
Posterior wall thickness, mm 9.2±1 9.8±2 0.1
E/A* 0.88 (0.63) 0.86 (0.63) 0.58
DT, ms 200±57.8 204.9±47.8 0.65
IVRT, ms 100.5±29.6 104.7±23.7 0.47
Sm, cm/s 8.8±2.3 9.5±3.0 0.22
E/Em 6.7±2.3 7.9±2.6 0.03
Em/Am* 0.88 (0.81) 0.65 (0.33) 0.41
Peak E’velocity, cm/s 10.3±3.5 9.6±4.1 0.23
Peak A’velocity, cm/s 10.7±3 12.4±4.6 0.06
*

Median (interquartile range)

DT - deceleration time; E/A - peak velocity of early diastolic flow/peak velocity of late diastolic flow; E/Em - peak velocity of early diastolic flow across mitral valve/peak septal annular velocity of early diastole; IVRT - isovolumetric relaxation time; IVST - interventricular septal thickness; LVEDD - left ventricular end-diastolic diameter; LVESD - left ventricular end-systolic diameter. Student's t-test and Mann–Whitney U test were used