Table 1.

Mechanical properties of materials used in biomechanical simulation.

Material Modulus of Elasticity (E)
Shear Modulus (G)
Poisson coefficient
Cortical bone Exx1=9.6E9Pa - Eyy2=9.6 E9Pa - Ezz3=1.78 E10Pa
Gxy4=3.097 E9Pa - Gxz5=3.51 E9Pa - Gyz6=3.51 E9Pa
Vxy7=0.46
Vxz8=0.30
Vyz9=0.30
Ti grade 5 1.1E11 Pa 0.33
Ti grade 4 1.05E11 Pa 0.37
Tooth 4.1E10 Pa 0.3
CoCrMo alloy 2.75E11 Pa 0.3