Skip to main content
. 2017 Feb 16;17(2):382. doi: 10.3390/s17020382

Table 2.

F values calculated by MANCOVA for 13 sensor channels.

Sensor F-Value Pr MISG
S10 350.50 2.20 × 10−16 Si-EPA-NA-MIP
S9 283.69 2.20 × 10−16 Si-EPA-HA-MIP
S6 104.36 1.28 × 10−14 Ti-EPA-HA-MIP
S3 87.04 1.11 × 10−13 Ti-BA-MIP
S8 63.41 4.34 × 10−12 Ti-TMP-BA-MIP
S2 62.78 4.86 × 10−12 Ti-NA-MIP
S13 61.69 5.92 × 10−12 Si-APT-NA-MIP
S11 42.96 3.23 × 10−10 Si-TMP-BA-MIP
S12 31.07 9.43 × 10−9 Si-APT-HA-MIP
S1 24.29 1.04 × 10−7 Ti-HA-MIP
S4 22.80 1.89 × 10−7 Ti-APT-HA-MIP
S5 15.79 4.76 × 10−6 Ti-APT-NA-MIP
S7 11.57 5.29 × 10−5 Ti-EPA-NA-MIP