Skip to main content
. 2016 Jun 2;41(1):298–301. doi: 10.1007/s12639-016-0776-3

Table 1.

Statistical parameters of different stains used for detecting of Pneumocystis jirovecii

Method No. of PSa/TPSb No. of NSc/TNSd SEN (%)e SPEC (%)f PPV (%)j NPV (%)h Time consumed (min) Cost consumed ($)
GMS 50/50 20/20 100 100 100 100 90 3.5
G 42/50 18/20 84 90 95.4 69.2 25 2
TB0 48/50 20/20 96 100 100 90.9 20 2.5

aPositive slides detected by methods

bTrue positive samples

cNegative slides detected by methods

dTrue negative samples

eSensitivity (measures the proportion of positives that are correctly identified)

fSpecificity (measures the proportion of negatives that are correctly identified)

jPositive predictive value (is the probability that subjects with a positive screening test truly are positive)

hNegative predictive value (is the probability that subjects with a positive screening test truly are positive)