Skip to main content
. 2017 Mar 6;6:e22152. doi: 10.7554/eLife.22152

Table 2.

Voltage-clamp protocol parameters for the five ion type classes. Times are stated in units of ms, voltages in units of mV. See Figure 3—figure supplement 1 for graphical description. Items TA* and TB* represent the starting and ending times, respectively, of the regions used for analysis (dashed areas in Figure 3 of the main text, as well as Figure 3—figure supplement 1).

DOI: http://dx.doi.org/10.7554/eLife.22152.019

Act Ion type V0 V1 V2 ΔV T1 T2 T3 TA* TB*
Kv −80 −80 70 10 100 500 100 100 700
Nav −80 −80 70 10 20 50 30 18 100
Cav −80 −80 70 10 100 500 100 98 700
KCa −80 −80 70 10 100 500 100 95 605
Ih −40 −150 0 10 100 2000 100 95 2105
Inact Ion Type V0 V1 V2 V3 ΔV T1 T2 T3 T4 TA* TB*
Kv −80 −40 70 30 10 100 1500 50 100 1600 1700
Nav −80 −40 70 30 10 100 1500 50 100 1580 1750
Cav −80 −40 70 30 10 100 1500 50 100 1580 1750
KCa −80 −40 70 30 10 100 1500 50 100 1595 1700
Ih −40 −150 −40 −120 10 100 1000 300 100 1095 1405
Deact Ion Type V0 V1 V2 V3 ΔV T1 T2 T3 T4 TA* TB*
Kv −80 70 −100 40 10 100 300 200 100 400 600
Nav −80 70 −100 40 10 20 10 30 20 29 80
Cav −80 70 −100 40 10 100 300 200 100 380 700
KCa −80 70 −100 40 10 100 300 200 100 395 605
Ih −40 −140 −110 0 10 100 1500 500 400 1595 2105
Ramp Ion Type V0 V1 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA* TB*
Kv −80 70 100 800 400 400 400 200 400 100 100 100 2800
Nav −80 70 100 800 400 400 400 200 400 100 100 98 2800
Cav −80 70 100 800 400 400 400 200 400 100 100 98 2800
KCa −80 70 100 800 400 400 400 200 400 100 100 100 2800
Ih −80 70 100 800 400 400 400 200 400 100 100 100 2800
AP Ion Type T1 TA* TB*
Kv 1800 100 1800
Nav 1800 98 1800
Cav 1800 98 1800
KCa 1800 95 1655
Ih 1800 95 1655