Skip to main content
. 2016 Jul 5;21(1):93–100. doi: 10.1007/s11325-016-1377-1

Table 3.

Improved difference from baseline without any appliance vs. with the use of an appliance

Monobloc appliance Bibloc appliance
Mean difference (SD) 95 % CI p a Mean difference (SD) 95 % CI p a
AHI 12.7 (11.6) 10.5;14.8 0.000 13.8 (14.8) 9.8;17.8 0.000
AI 8.3 (9.1) 6.6;10.1 0.000 8.0 (1.6) 4.8;11.3 0.000
ODI 11.0 (11.3) 8.9;13.2 0.000 12.2 (13.7) 8.4;16.1 0.000
Lowest SpO2 (%) 3.0 (6.1) 1.7;4.2 0.000 2.1 (5.6) 0.5:3.6 0.000
Longest apnea (sec) 15.2 (19.4) 11.1;19.3 0.000 11.0 (20.0) 5.0;17.0) 0.001
ESS 3.1 (4.0) 2.2;3.9 0.000 2.6 (4.3) 1.0:4.1 0.002

AHI apnea hypopnea index, AI apnea index, ODI oxygen desaturation index, SpO 2 oxygen saturation, ESS Epworth sleepiness scale

a p value reflects the difference within the treatment group